Customization: | Available |
---|---|
Application: | Automotive Harnessing, Communication industry, Machine Protection, Wire & Cable Protection |
Color: | Customized |
Still deciding? Get samples of US$ 0.1/Piece
Order Sample
|
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
RUBLS-EPDM a series of open-ended, tubular rubber sleeves, which are factory expanded and assembled onto a removable core. They are supplied for field installation in this pre-stretched condition. The core is removed after the tube has been positioned for installation over an in line connection, terminal lug, etc., allowing the tube to shrink and form a waterproof seal. The insulation tube is made of EPDM rubber, which contains no
chlorides or sulphurs. Various diameter sizes will cover a range of 1000 volt cables, copper and aluminum conductors.
Features
• Excellent weather resistance, ultraviolet aging resistance and higher embrittlement resistance than heat
shrink tubing
• More resistant to slab and prick, abrasion, acid and alkali than silicone cold shrink tubing
• Simultaneously expands and shrinks with workpieces without clearances, seals tight in harsh
environment
• Stably sealing the workpieces in windy environment
• Well suited for cable less than 1KV
• Seals tight, retains its resiliency and pressure even after prolonged years of ageing and exposure
• Simple, safe installation, requires no tools or special training. No torches or heat work required
• Diameter shrinkage:±50%
• Sealing class IP68
Technical Data
Item | Typical Data | Test method |
Hardness Shore | 45±5A | GB/T 531.1 |
Tensile Strength | ≥8.6MPa | GB/T 528 |
Elongation at break | ≥600% | GB/T 528 |
Tear Strength | ≥25MPa | GB/T 529 |
Dielectric Strength | 15kV/mm | ASTM D149 |
Size (mm) |
Inner Diameter D(mm) | Min Cable Outer Diameter (mm) | Max Cable Outer Diameter (mm) | Recovered Length L(mm) |
VE25-8 | 25 | 10.1 | 20.9 | 203 |
VE35-11 | 35 | 13.9 | 30.1 | 279 |
VE42-16 | 42 | 17.0 | 37.0 | 406 |
VE58-12 | 58 | 24.0 | 49.3 | 305 |
VE77-12 | 77 | 32.2 | 67.8 | 305 |
VE120-24 | 120 | 56.0 | 110.0 | 610 |
Size is available to customize